2025-05-27 18:58:27R. Bishop:
Update to BS5839:2025
fire alarms/regulations/bs 5839.md ..
@@ 2,91 2,105 @@
## Understanding BS 5839
-
**BS 5839** is the British Standard that provides guidance on the **design, installation, commissioning, and maintenance of fire detection and alarm systems** in buildings. It is an essential document for ensuring compliance with fire safety laws and best practices, particularly in non-domestic buildings such as offices, schools, hospitals, and industrial sites.
+
**BS 5839** is the British Standard that sets out best practice recommendations for the **design, installation, commissioning, and maintenance of fire detection and alarm systems**. It plays a vital role in achieving compliance with UK fire safety legislation, particularly in non-domestic buildings such as offices, schools, healthcare facilities, and commercial premises.
-
BS 5839 is divided into two key parts:
+
BS 5839 is split into two major parts:
-
- **BS 5839-1** → Covers fire alarm systems in **non-domestic buildings**.
-
- **BS 5839-6** → Covers fire alarm systems in **domestic premises**.
+
* **BS 5839-1** → Applies to fire detection and alarm systems in **non-domestic premises**.
+
* **BS 5839-6** → Covers systems used in **domestic (residential) premises**.
-
This document primarily focuses on **BS 5839-1**, which applies to commercial and public buildings.
+
This page focuses on the updated **BS 5839-1:2025** edition, which replaces the 2017 version.
---
-
## Why BS 5839 is Essential for Fire Alarm Systems
+
## Why BS 5839-1:2025 is Essential for Fire Alarm Systems
-
Compliance with **BS 5839-1** is crucial because it:
+
Compliance with **BS 5839-1:2025** helps to:
-
- **Ensures life safety** by providing early fire detection and warning systems.
-
- **Reduces property damage** by enabling faster emergency response.
-
- **Meets legal and insurance requirements**, ensuring compliance with fire safety laws.
-
- **Enhances system reliability**, reducing false alarms and improving performance.
+
* Improve **life safety** by enabling early warning and effective evacuation.
+
* Reduce **property damage** through prompt detection and fire brigade response.
+
* Satisfy **legal obligations** under fire safety laws like the **Regulatory Reform (Fire Safety) Order 2005**.
+
* Provide a structured approach to **system reliability**, false alarm reduction, and robust documentation.
-
BS 5839 does not impose a legal obligation but is widely used as the standard reference for compliance with the **Regulatory Reform (Fire Safety) Order 2005 (FSO)** and other fire safety legislation.
+
While it is not a legal document in itself, BS 5839-1 is widely used to demonstrate compliance with statutory fire safety duties.
---
-
## Key Parts of BS 5839 Relevant to Fire Alarm Systems
+
## Key Changes Introduced in the 2025 Edition
-
Several key sections of **BS 5839-1** are essential for ensuring that fire alarm systems meet safety and performance requirements.
+
### **Clause Restructuring and New Section**
-
### **System Categories and Coverage**
+
* **Clause 4** has been moved into the **Introduction**.
+
* **Clause 33** on false alarms is now integrated with Clause 31.
+
* A new **Section 7** has been added, covering **extensions and modifications** to existing systems.
-
BS 5839 defines fire alarm system categories based on their intended purpose:
+
### **Stricter Variation Controls**
-
- **Category M** → Manual fire alarm systems (requires manual call points, no automatic detection).
-
- **Category L** → Life protection systems (L1 to L5, based on coverage and risk levels).
-
- **Category P** → Property protection systems (P1 and P2, focusing on early fire detection to reduce property loss).
+
* Certain departures from recommendations are now clearly stated as **unacceptable** in Clause 6. For example, omitting a zone plan in multi-zone buildings is not permitted.
-
Each category specifies the required level of fire detection coverage within a building.
+
### **Improved Manual Call Point Guidance**
-
### **Design Considerations**
+
* Siting rules have been simplified. Manual call points must be no more than **45m travel distance**, or **30m if the layout is uncertain**.
-
This section outlines key factors to consider when designing a fire alarm system:
+
### **Detector Use in Sleeping Accommodation**
-
- **Fire risk assessment** → Identifying risks to determine appropriate system coverage.
-
- **Detector selection** → Choosing between smoke, heat, or multi-sensor detectors based on environmental factors.
-
- **Alarm audibility requirements** → Ensuring sounders and voice alarms meet minimum decibel levels for occupant warning.
-
- **False alarm management** → Implementing measures to minimize nuisance alarms and improve system reliability.
+
* The standard now advises against using heat detectors in sleeping rooms, recommending faster-reacting alternatives instead.
-
### **Installation Requirements**
+
### **Cybersecurity Considerations**
+
+
* Clause 43.4 includes requirements for **cybersecurity and remote services**, acknowledging modern system vulnerabilities.
+
+
---
+
+
## Key Elements of BS 5839-1:2025 for Fire Alarm Systems
-
To ensure fire alarms function effectively, BS 5839 specifies strict installation guidelines:
+
### **System Categories and Purpose**
-
- **Cabling** → Fire-resistant cables must be used and correctly routed to prevent failure in a fire.
-
- **Power supplies** → Systems must have reliable **mains power** and **battery backup** to prevent failure during outages.
-
- **Spacing of call points and detectors** → Manual call points should be positioned near exits, and detectors must be installed at appropriate intervals for full coverage.
+
* **Category M** → Manual systems without automatic detection.
+
* **Category L** → Life protection (L1 to L5, based on risk).
+
* **Category P** → Property protection (P1 or P2).
-
### **Testing & Maintenance**
+
Each category outlines specific detection coverage and design principles.
+
+
### **System Design Considerations**
+
+
* **Risk-Based Design** → System layout must be informed by a fire risk assessment.
+
* **Detector Selection** → Match detector types to environmental risks (e.g. avoid heat in sleeping areas).
+
* **Alarm Performance** → Sound pressure levels must be sufficient for clear occupant warning.
+
* **False Alarm Strategy** → Use appropriate siting, configuration, and detection technologies to reduce nuisance activations.
+
+
### **Installation Requirements**
-
Regular **inspection, testing, and maintenance** are essential for ensuring fire alarm systems remain operational and compliant.
+
* **Cabling** → Must be fire-resistant and installed using appropriate support systems.
+
* **Power Supply** → Both mains and compliant standby battery supply must be verified.
+
* **Call Point and Detector Positioning** → Follow updated distance limits and placement rules.
-
- **Weekly tests** → The responsible person must test a manual call point every week.
-
- **Quarterly servicing** → A competent fire alarm engineer must inspect and test the system every three months.
-
- **Annual servicing** → A full system inspection must be carried out yearly to check all devices and connections.
-
- **False alarm management** → Records of false alarms must be reviewed, and appropriate actions taken to reduce unnecessary activations.
+
### **Inspection and Maintenance**
-
Failure to maintain a fire alarm system as per BS 5839 could lead to non-compliance with **fire safety laws** and **insurance invalidation** in the event of a fire.
+
* **Weekly Testing** → Test a manual call point each week.
+
* **Monthly Checks** → Inspect batteries and verify charging systems.
+
* **Annual Servicing** → Comprehensive testing of all components.
+
* **Logbook Maintenance** → Record tests, faults, false alarms, and maintenance actions.
---
## Consequences of Non-Compliance
-
Failing to comply with **BS 5839-1** can result in:
+
Failure to comply with BS 5839-1:2025 can result in:
-
- **Increased risk to life and property** due to inadequate fire detection.
-
- **Legal penalties** if the system does not meet fire safety requirements under UK law.
-
- **Higher false alarm rates**, leading to potential fines or loss of trust in the system.
-
- **Insurance disputes**, as insurers may refuse claims if the system was not properly maintained.
+
* **Increased safety risk** due to ineffective alarm coverage.
+
* **Legal action** under fire safety legislation.
+
* **Frequent false alarms**, risking fines or loss of confidence in system performance.
+
* **Insurance issues**, including potential refusal of claims after a fire.
---
## Final Thoughts
-
**BS 5839-1 is the foundation for designing and maintaining effective fire alarm systems in non-domestic buildings.** By following its requirements, responsible persons, installers, and maintenance engineers can ensure:
+
**BS 5839-1:2025** reflects modern best practices and addresses lessons learned from fire incidents. Compliance supports:
-
✅ **Compliance with fire safety laws and regulations.**
-
✅ **A reliable system that minimizes false alarms.**
-
✅ **Protection of lives and property.**
+
✅ Safer buildings and occupants.
+
✅ Fewer false alarms.
+
✅ Legal and insurance alignment.
-
Whether planning, installing, or maintaining a fire alarm system, **adhering to BS 5839 is essential for safety, legal compliance, and system effectiveness.**
+
Whether you're designing, installing, or maintaining a fire alarm system, applying the updated BS 5839-1 is essential to uphold safety, legal duties, and system performance.